Quality Assurance / After-sales Worry-free Service
Commercial Food Waste Reduction Unit
Product OverviewThis is an on‑site waste‑reduction unit designed for food waste generated from commercial and institutional kitchens.Key SpecificationsItemSpecificationStandard treatment capacity99 kg/dayOverall dimensions2104 × 1404 × 1309 mmEquipment weight1500 kgTreatment methodMicrobial fermentation and decompositionOperating temperature45‑55 °CTable of ContentsDevelopment Partners and Facilities 03
Fermentation & Decomposition Process 04
Product Specifications and Sample Analysis 05
Installation and Scope of Work 06
Acceptance and Maintenance 07Development Partners and FacilitiesThe ECODAM 100 commercial food waste reduction unit is jointly developed by MIRAE ECOTECH Co., Ltd. and Xinxiang Ruite Machinery Co., Ltd.
‑ MIRAE ECOTECH Co., Ltd.: An organic waste‑treatment enterprise based in South Korea
‑ Xinxiang Ruite Machinery Co., Ltd.: Manufacturing facility located in Xinxiang, Henan Province, ChinaIllustration: On‑site photograph of the Ruite Machinery plant in Xinxiang, Henan
Photo source: Ruite Machinery factory gallery
Additional photos: Material turning at the waste‑treatment site; Ruite Machinery production workshopMIRAE ECOTECH delivers on‑site food‑waste reduction solutions tailored to waste output, on‑site installation constraints and operational requirements.
Ruite Machinery specialises in organic‑fertilizer production lines, compost turners, mixers and screening equipment.Typical Application ScenariosFacility TypeOn‑site Evaluation CriteriaInstitutional kitchensPeak volumes of post‑meal waste, operating days, waste‑collection routesWorkplace cafeteriasWaste output per shift, peak‑day feeding plan, service‑vehicle accessCommercial kitchensPrep‑generated waste plus plate leftovers, contaminant removal, exhaust‑duct routingTreatment Process: Fermentation and DecompositionSorted food waste is fed into the treatment chamber. Process exhaust gas and residual output material are managed separately.Process flow chart: Sorting & Weighing → Feeding & Loading → Mixing, Fermentation & Decomposition (temperature control + air circulation). Two output streams are generated: Residual Material and Exhaust Odour Control (platinum catalyst + thermal incineration).
Sorting & Weighing: Remove contaminants and record feed weight
Feeding & Loading: Transfer materials into the treatment chamberPre‑feeding Material RequirementsOperation CategoryMaterial RequirementsItems to be removedPackaging, metals, glass, large bones, shells, hard fruit pitsMaterials requiring advance assessmentHigh‑liquid, high‑salt and high‑grease food‑waste streamsOn‑site trial photographs: Feed and mixing chamber during trial run; interior of mixing chamber after trial completionProduct Specifications and Sample AnalysisModel parameters together with laboratory test results for one sample documented in source materials.Equipment Parameter SheetParameterSpecificationModelECODAM 100Equipment type99 kg‑class commercial food‑waste reduction unitStandard treatment capacity99 kg/dayTreatment methodMicrobial fermentation and decompositionFunctional microorganismsLactobacillus group (refer to full model specifications)Overall dimensions2104 × 1404 × 1309 mmEquipment weight1500 kgOperating temperature45‑55 °CPower supply380 V (220 V single‑phase configuration available)Odour‑control methodPlatinum catalyst combined with thermal incinerationResidual‑Material Laboratory Test ReportTesting Laboratory: AT Analysis Center Co., Ltd.
Sample receipt No.: 21‑05‑R296
Report issue date: 27 May 2021
Sample type: Food waste and vegetable‑based organic matterOrganic MatterMoisture ContentSalt Content (dry basis)Organic‑Matter‑to‑Nitrogen Ratio55.42 %20.06 %0.45 %74.89Note: Results apply solely to this single submitted sample. The organic‑matter‑to‑nitrogen ratio of this sample exceeded the report reference limit of 45.
Independent verification is required for actual equipment performance and the suitability of residual material for fertiliser applications.On‑site Installation and Scope of WorkSite access and equipment placement must be reviewed prior to finalising electrical and exhaust‑system designs.Delivery Access ConditionsDoorway widths, turning clearances, inter‑floor transfer space; packaged equipment dimensions, transport and lifting arrangements.Floor Loading and Service AccessUnit dead‑weight of 1500 kg plus dynamic operating loads. Maintain clear working space for feeding, inspection and component replacement.Electrical Installation WorksMatch site voltage and phase configuration to unit specifications. Confirm power supply circuits, circuit breakers, wiring and earthing arrangements.Ventilation and Material LogisticsExhaust‑duct routing and discharge‑point location; routes for material feeding, container washing and residue removal.Reference layout of equipment during field demonstration. Delivery and installation requirements shall be individually confirmed for each project.Documentation Required for Site AssessmentDocument CategoryRequired InformationSite‑related documentsFloor plans, on‑site photographs, access dimensions, power‑supply and exhaust‑outlet locationsOperating‑condition dataAverage‑ and peak‑day waste volumes, feedstock composition, operating days, waste‑generation time windowsEquipment documentationGeneral‑arrangement and installation drawings, rated power, supply frequency, exhaust‑port specifications, batch‑feed limits, additive replenishment requirements